Digitala Vetenskapliga Arkivet

Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Accuracy and precision of zero-echo-time, single- and multi-atlas attenuation correction for dynamic [11C]PE2I PET-MR brain imaging
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Radiologi.ORCID-id: 0000-0002-1498-1327
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Radiologi.
Vise andre og tillknytning
2020 (engelsk)Inngår i: EJNMMI Physics, E-ISSN 2197-7364, Vol. 7, nr 1, artikkel-id 77Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

BACKGROUND: A valid photon attenuation correction (AC) method is instrumental for obtaining quantitatively correct PET images. Integrated PET/MR systems provide no direct information on attenuation, and novel methods for MR-based AC (MRAC) are still under investigation. Evaluations of various AC methods have mainly focused on static brain PET acquisitions. In this study, we determined the validity of three MRAC methods in a dynamic PET/MR study of the brain.

METHODS: Nine participants underwent dynamic brain PET/MR scanning using the dopamine transporter radioligand [11C]PE2I. Three MRAC methods were evaluated: single-atlas (Atlas), multi-atlas (MaxProb) and zero-echo-time (ZTE). The 68Ge-transmission data from a previous stand-alone PET scan was used as reference method. Parametric relative delivery (R1) images and binding potential (BPND) maps were generated using cerebellar grey matter as reference region. Evaluation was based on bias in MRAC maps, accuracy and precision of [11C]PE2I BPND and R1 estimates, and [11C]PE2I time-activity curves. BPND was examined for striatal regions and R1 in clusters of regions across the brain.

RESULTS: For BPND, ZTE-MRAC showed the highest accuracy (bias < 2%) in striatal regions. Atlas-MRAC exhibited a significant bias in caudate nucleus (- 12%) while MaxProb-MRAC revealed a substantial, non-significant bias in the putamen (9%). R1 estimates had a marginal bias for all MRAC methods (- 1.0-3.2%). MaxProb-MRAC showed the largest intersubject variability for both R1 and BPND. Standardized uptake values (SUV) of striatal regions displayed the strongest average bias for ZTE-MRAC (~ 10%), although constant over time and with the smallest intersubject variability. Atlas-MRAC had highest variation in bias over time (+10 to - 10%), followed by MaxProb-MRAC (+5 to - 5%), but MaxProb showed the lowest mean bias. For the cerebellum, MaxProb-MRAC showed the highest variability while bias was constant over time for Atlas- and ZTE-MRAC.

CONCLUSIONS: Both Maxprob- and ZTE-MRAC performed better than Atlas-MRAC when using a 68Ge transmission scan as reference method. Overall, ZTE-MRAC showed the highest precision and accuracy in outcome parameters of dynamic [11C]PE2I PET analysis with use of kinetic modelling.

sted, utgiver, år, opplag, sider
2020. Vol. 7, nr 1, artikkel-id 77
Emneord [en]
Atlas, Binding potential, Dopamine transporter, MRAC, MaxProb, ZTE, rCBF
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-430223DOI: 10.1186/s40658-020-00347-2ISI: 000603296900001PubMedID: 33369700OAI: oai:DiVA.org:uu-430223DiVA, id: diva2:1515126
Forskningsfinansiär
Swedish Research Council, 2011-6269Region Uppsala
Merknad

De två första författarna delar förstaförfattarskapet

Tilgjengelig fra: 2021-01-08 Laget: 2021-01-08 Sist oppdatert: 2022-06-07bibliografisk kontrollert
Inngår i avhandling
1. Assessment of attenuation correction methods for quantitative neuro-PET/MR
Åpne denne publikasjonen i ny fane eller vindu >>Assessment of attenuation correction methods for quantitative neuro-PET/MR
2021 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

Hybrid PET/magnetic resonance (MR) can provide physiological, functional, and structural information simultaneously, facilitating research in neurological disorders. For quantitative PET, correction for photon attenuation (AC) is necessary. However, in contrast to dedicated PET and PET/computed tomography (CT) systems, PET/MR has no direct possibility to measure photon attenuation. As such, MR-based methods are required for AC (MRAC), and these need to be thoroughly validated before clinical implementation.

The primary aim of this thesis was to evaluate two vendor-provided MRAC methods (single-atlas and zero echo time, ZTE), a previously published maximum probability (MaxProb) method, and a composite transmission scan atlas (CTR) method for a SIGNA PET/MR. This evaluation was done both in terms of absolute quantification in static scans and of outcome measures of tracer kinetic modelling based on dynamic scans. The secondary aim was to compare quantitative brain PET measurements acquired on the SIGNA PET/MR with those acquired on a dedicated PET scanner. Ten patients with parkinsonism who underwent dynamic dopamine transporter scans using 11C-PE2I in a PET/MR and dedicated PET were included. Standardized uptake values (SUV), binding potential (BPND), and relative delivery (R1) were assessed at volume of interest (VOI) and voxel level to compare the various MRAC methods with the gold-standard, a 68Ge transmission scan, and to compare quantitative outcomes between scanners.

In general, ZTE provided the highest precision in SUV, R1 and BPND, showing the least inter-subject variability in bias compared to 68Ge-transmission AC, whereas MaxProb and CTR showed the lowest precision. Contrary to this, accuracy of absolute SUV values was best for CTR followed by MaxProb, with ZTE showing a homogeneous positive bias of about 10%. ZTE provided the highest accuracy in outcome measures of tracer kinetic analysis. Differences in quantitative results between stand-alone PET and PET/MR exceeded what can be explained by difference in AC alone, although they were still comparable to previously published test-retest variability of 11C-PE2I. Additionally, an activation in the auditory cortex was seen in PET data from the PET/MR because of the noise produced by the MR gradients.

ZTE-MRAC appears to be the best method for dynamic scanning and tracer kinetic analysis using reference methods, while CTR- and MaxProb-MRAC appear the most appropriate for absolute quantification. Also, attention should be taken to the auditory cortex activation in R1 images when comparing data from PET/MR and other PET- systems.

sted, utgiver, år, opplag, sider
Uppsala: Acta Universitatis Upsaliensis, 2021. s. 65
Serie
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Medicine, ISSN 1651-6206 ; 1751
Emneord
PET, MRI, attenuation correction, 68Ge transmission, quantification, 11C-PE2I, MRAC, DAT, CBF
HSV kategori
Forskningsprogram
Medicinsk radiofysik
Identifikatorer
urn:nbn:se:uu:diva-440386 (URN)978-91-513-1215-6 (ISBN)
Disputas
2021-06-11, H:son-Holmdahlsalen, Akademiska sjukhuset, 100/101, 2 tr, Uppsala, 13:00 (engelsk)
Opponent
Veileder
Tilgjengelig fra: 2021-05-19 Laget: 2021-04-21 Sist oppdatert: 2021-06-21

Open Access i DiVA

fulltext(2578 kB)195 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 2578 kBChecksum SHA-512
2382ea2ca525a38121c3162f0d3fafa2f88d807f25a10bca1595d19d9d979e185e6d043a7cc00f1b04c80798975e13f5b76aab62f5402268f7761decba7a587e
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstPubMed

Søk i DiVA

Av forfatter/redaktør
Sousa, João M.Appel, LieuweNyholm, DagAhlström, HåkanLubberink, Mark
Av organisasjonen
I samme tidsskrift
EJNMMI Physics

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 196 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 105 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf