Digitala Vetenskapliga Arkivet

Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Development of a clinically feasible [11C]PE2I PET method for differential diagnosis of parkinsonism using reduced scan duration and automated reference region extraction.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Radiologi.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Radiologi.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Radiologi.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för neurovetenskap, Neurologi.ORCID-id: 0000-0001-9776-7715
Vise andre og tillknytning
2017 (engelsk)Inngår i: American Journal of Nuclear Medicine and Molecular Imaging, ISSN 2160-8407, Vol. 7, nr 6, s. 263-274Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

[11C]PE2I is a highly selective dopamine transporter PET ligand. Parametric images based on dynamic [11C]PE2I scans, showing dopamine transporter availability (BPND) and relative cerebral blood flow (R1), can be used in differential diagnosis of parkinsonism. This work aimed to investigate a shortened scan duration and automated generation of parametric images which are two prerequisites for routine clinical application. Twelve subjects with parkinsonism and seventeen healthy controls underwent 80 min dynamic [11C]PE2I PET scans. BPND and R1 images were generated using cerebellum reference region defined on a co-registered MRI, as well as a supervised cluster analysis (SVCA)-based reference. Initial 20, 30 and 40 min of the scans were extracted and images of standardized uptake value ratio (SUVR) and R1 were computed using MRI- and SVCA-based reference. Correlation was high between striatal 80 min MRI-based BPND and 40 min SVCA-based SUVR-1 (R2=0.95). High correlation was also found between R1 values in striatal and limbic regions (R2≥0.91) whereas correlation was moderate for cortical regions (R2=0.71). The results indicate that dynamic [11C]PE2I scans can be restricted to 40 min and that SVCA can be used for automatic extraction of a reference region. These outcomes will support routine applications of [11C]PE2I PET in clinical settings.

sted, utgiver, år, opplag, sider
2017. Vol. 7, nr 6, s. 263-274
Emneord [en]
PET, [11C]PE2I, parametric images, parkinsonism, supervised clustering
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-340790ISI: 000419593300003PubMedID: 29348981OAI: oai:DiVA.org:uu-340790DiVA, id: diva2:1179814
Forskningsfinansiär
Swedish Research CouncilSwedish Society for Medical Research (SSMF)Tilgjengelig fra: 2018-02-02 Laget: 2018-02-02 Sist oppdatert: 2018-02-21bibliografisk kontrollert
Inngår i avhandling
1. Towards Clinical Implementation of Dynamic Positron Emission Tomography in Neurodegenerative Diseases
Åpne denne publikasjonen i ny fane eller vindu >>Towards Clinical Implementation of Dynamic Positron Emission Tomography in Neurodegenerative Diseases
2018 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

Alzheimer’s disease (AD) and Parkinson’s disease (PD) are the two most common neurodegenerative disorders worldwide. Positron emission tomography (PET), together with suitable biomarkers, can aid in the clin-ical evaluation as well as in research investigations of these diseases. Straightforward and quantitative assessments of the parameters of inter-est estimated on a voxel-level, as parametric images, are possible when PET data is acquired over time. Prerequisites to facilitate clinical use of dynamic PET are simplified analysis methods and scan protocols suita-ble for clinical routine.

The aim of this thesis was to validate simplified analysis methods, suitable for clinical use, for quantification of dopamine transporter (DAT) availability in patients with parkinsonism using [11C]PE2I PET and tau accumulation in AD patients with [18F]THK5317 PET.

The included subjects comprised of both healthy controls and pa-tients with parkinsonism, AD or mild cognitive impairment and each subject underwent a dynamic PET scan with either [11C]PE2I or [18F]THK5317. Models for quantitative voxel-based analysis, resulting in parametric images of tracer binding and overall brain function, were validated in both patients and controls. These parametric methods were compared to region-based values acquired using both plasma- and refer-ence-input models. Clinically feasible scan durations were evaluated for both [11C]PE2I and [18F]THK5317, and a clustering method to obtain a reference time activity curve directly from the dynamic PET data was validated. Furthermore, images of DAT availability and overall brain functional activity, generated from one single dynamic [11C]PE2I PET scan, were compared to a dual-scan approach using [123I]FP-CIT single photon emission computed tomography (SPECT) and [18F]FDG PET, for differential diagnosis of patient with parkinsonism.

Study I-III supply valuable information on the feasibility of dynamic [11C]PE2I in a clinical setting for differential diagnosis of parkinsonian disorders, by having easily accessible images of DAT availability and overall brain functional activity. The work in study IV-V showed that reference methods can be used for quantification of tau accumulation, and suggests that simplified analysis methods and shorter scan durations can be applied to further facilitate applications of dynamic [18F]THK5317 PET.

sted, utgiver, år, opplag, sider
Uppsala: Acta Universitatis Upsaliensis, 2018. s. 55
Serie
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Medicine, ISSN 1651-6206 ; 1429
Emneord
Positron emission tomography, PET, Molecular imaging, Quantification, Kinetic modelling, Parametric images, Alzheimer’s disease, Parkinson’s disease
HSV kategori
Forskningsprogram
Radiologi
Identifikatorer
urn:nbn:se:uu:diva-341786 (URN)978-91-513-0238-6 (ISBN)
Disputas
2018-04-06, Skoogsalen, Akademiska Sjukhuset, Ing 79, Uppsala, 09:15 (engelsk)
Opponent
Veileder
Tilgjengelig fra: 2018-03-14 Laget: 2018-02-15 Sist oppdatert: 2018-04-24

Open Access i DiVA

fulltext(1549 kB)216 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1549 kBChecksum SHA-512
0f9d0a99ce2e4c3b0f7576f4fe066834b0f2b2fdae1249ff5b96300209057cb4969b41c0d3bccde55c57760bab2b2738f7b3152401b83a3a21ceb1c8444f1b57
Type fulltextMimetype application/pdf

Andre lenker

PubMedhttps://www.ncbi.nlm.nih.gov/pmc/articles/PMC5768921/

Søk i DiVA

Av forfatter/redaktør
Jonasson, MyAppel, LieuweDanfors, TorstenNyholm, DagAskmark, HåkanFrick, AndreasEngman, JonasFurmark, TomasSörensen, JensLubberink, Mark
Av organisasjonen
I samme tidsskrift
American Journal of Nuclear Medicine and Molecular Imaging

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 216 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

pubmed
urn-nbn

Altmetric

pubmed
urn-nbn
Totalt: 136 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf